Go back to datasheets

PEEK-OPTIMA™ Natural LT1 (Large Rods Ø 70-180 mm and Plates)

High performance biocompatible thermoplastic material, PolyEtherEtherKetone (PEEK), semi crystalline. Stockshape rod diameters between 70–180mm and plates for machining, for use in long term human implantation. Colour natural/beige.

Typical Application Areas
For use in applications requiring high strength, high stiffness, and high ductility. Suitable for use in long-term implantable medical devices. Excellent sterilisation resistance. As PEEK is hygroscopic, drying before use is recommended. Further information is available upon request.

PEEK-OPTIMA™ is known for its outstanding biocompatibility, chemical resistance, and mechanical strength. PEEK-OPTIMA™ Natural provides a reliable and versatile solution for short and long-term implants.

Material Properties
Physical

Nominal Value

Unit

Test Method

Density (23°C)

1.31

g/cm³

ISO 1183

Water Absorption (Equilibrium, 23°C, 50% RH)

0.50

%

ISO 62

Crystallinity DSC

42.0

%

Internal Method
Mechanical

Nominal Value

Unit

Test Method

Tensile Stress (Yield, 23°C)

115

MPa

ISO 527-2

Tensile Strain (Break, 23°C)

22

%

ISO 527-2

Flexural Modulus (23°C)

4400

MPa

ISO 178

Flexural Stress

ISO 178

Yield, 23°C

188

MPa

3.5% Strain, 23°C

149

MPa

Impact

Nominal Value

Unit

Test Method

Notched Izod Impact Strength (23°C)

5.5

kJ/m²

ISO 180
Thermal

Nominal Value

Unit

Test Method

Glass Transition Temperature (Onset)

145

°C

ISO 11357-2

Melting Temperature

341

°C

ISO 11357-3

Recrystallization Temperature (Peak)

293

°C

ISO 11357-3
Additional Information

Important Notes
1) Processing conditions quoted in our datasheets are typical of those used in our processing laboratories.
2) Data are generated in accordance with prevailing national, international and internal standards, and should be used
for material comparison. Actual property values are highly dependent on part geometry and processing conditions.
Properties may also differ for along flow and across flow directions.
3) Invibio strongly recommend following the PEEK-OPTIMA™ Machining Guidelines prior to machining to reduce
stresses and perform optimal machining techniques.

Storage Requirements
Store in original packaging away from direct sunlight and extremes of temperatures. Do not use if sealing tab is broken
prior to opening.

Development Material
During qualification activities NFHI (Not For Human Implantation) grades are available upon request.

Detailed data available on our website www.invibio.com or upon request.

PEEK-OPTIMA Natural LT1 Large Rods and Plates