Go back to datasheets

PEEK-CLASSIX™ BC2-WH (Granules)

High performance biocompatible thermoplastic material, white compounded PolyEtherEtherKetone (PEEK), semi crystalline. Granules for injection moulding and extrusion, medium flow, suitable for medical devices that will be in contact with human tissue for 30 days or less. Colour white.

Typical Application Areas
For use in applications requiring high strength, high stiffness, and high ductility. Suitable for medical devices that will be in contact with human tissue for 30 days or less. As PEEK is hygroscopic, drying before use is recommended. Further information is available upon request.

PEEK-CLASSIX™ offers a high-performance polymer solution with a low level of extractables and leachables, and chemical resistance to drug concentrates, and the extremes found within the human body.

Material Properties
Physical

Nominal Value

Unit

Test Method

Density (23°C)

1.39

g/cm³

ISO 1183

Melt Mass-Flow Rate (MFR) (400°C/2.16 kg)

5.9

g/10 min

Internal Method

Spiral Flow 1

11.0

cm

Internal Method

Molding Shrinkage

ASTM D955

Flow

1.1

%

Across Flow

1.4

%

Water Absorption (Equilibrium, 23°C, 50% RH)

0.58

%

ISO 62

Crystallinity DSC

31.0

%

Internal Method
Mechanical

Nominal Value

Unit

Test Method

Tensile Stress (Yield, 23°C)

99.5

MPa

ISO 527-2

Tensile Strain (Break, 23°C)

18

%

ISO 527-2

Flexural Modulus (23°C)

4190

MPa

ISO 178

Flexural Stress

ISO 178

Yield, 23°C

164

MPa

3.5% Strain, 23°C

131

MPa

Impact

Nominal Value

Unit

Test Method

Notched Izod Impact Strength (23°C)

6.1

kJ/m²

ISO 180
Thermal

Nominal Value

Unit

Test Method

Glass Transition Temperature (Onset)

145

°C

ISO 11357-2

Melting Temperature

342

°C

ISO 11357-3

Recrystallization Temperature (Peak)

288

°C

ISO 11357-3
Fill Analysis

Nominal Value

Unit

Test Method

Melt Viscosity 1000 s^-1 (400°C)

398

Pa·s

Internal Method

Melt Stability 1000 s^-1, 1 hr (400°C)

0.91

%

Internal Method
Typical Processing Information
Injection

Nominal Value

Unit

Drying Temperature

120 to 150

°C

Drying Time

3.0 to 5.0

hr

Suggested Max Moisture

0.020

%

Hopper Temperature

< 100

°C

Rear Temperature

350

°C

Middle Temperature

355 to 365

°C

Front Temperature

370

°C

Nozzle Temperature

370

°C

Mould Temperature

170 to 200

°C

Injection Notes

Drying Temperature / Time: 150°C / 3h or 120°C / 5h (residual moisture <0.02%)
Runner: Die / Nozzle >3 mm, Manifold >3.5 mm
Gate: >1 mm or 0.5 x part thickness

Important Notes:
1) Processing conditions quoted in our datasheets are typical of those used in our processing laboratories

  • Data for mould shrinkage should be used for material comparison. Actual mould shrinkage values are highly dependent on part geometry, mould configuration, and processing conditions.
  • Mould shrinkage differs for along flow and across flow directions. “Along flow” direction is taken as the direction the molten material is travelling when it exits the gate and enters the mould.
  • Mould shrinkage is expressed as a percent change in dimension of a specimen in relation to mould dimensions.

2) Data are generated in accordance with prevailing national, international and internal standards, and should be used for material comparison. Actual property values are highly dependent on part geometry, mould configuration and processing conditions. Properties may also differ for along flow and across flow directions.

Detailed data available on our website www.invibio.com or upon request.

Notes
11.00 mm
PEEK-CLASSIX BC2-WH Granules